NEXTERION® HiSens Slides

 

The majority of microarray users prefer to use fluorescent dyes as labels in their experiments, as these dyes typically offer high sensitivity and enable the detection of two or more different dyes simultaneously. Unfortunately, microarray scanners are not able to operate at their maximum efficiency, as the detectors do not acquire all the total emitted fluorescence.
There are a number of factors that contribute to the inefficient signal capture:
  • Only a proportion of the total excitation light is absorbed by the micro array spots, with most passing through the glass slide.
  • On standard non-reflective slides, there is weak, but “destructive” interference of the excitation light waves, leading to a lower fluorescent emission.
  • The light emitted by the fluorescent dyes attached to the target molecule is undirected and lost through the back of the transparent glass.
To address these problems, SCHOTT has utilized its extensive optical glass coating expertise to develop the next generation of microarray slides – NEXTERION® HiSens (HighSensitivity).
 

Overview

Type of coatingOrdering information
NEXTERION®productBarcode optionItem numberSlides per pack
Reflective optical coating available with most of NEXTERION® functional coatingsHiSens uncoatedNone114151825
Label114151925
HiSens AStarNone117804525
Label117804625
HiSens A+None113967325
Label114151525
HiSens ALNone113982725
Label114151425
HiSens ENone112581325
Label113733225
HiSens HNone114151725
Label113982925
HiSens PNone117805125
Label117805225
Key product features
• Significantly improved signal to background ratios for identifying low-expressor genes or low-abundant proteins
• Easy implementation with standard slide protocols
• Compatible with all common microarray equipment
• Reduced target concentrations
• Reduced reagents and dye costs
• Preservation of Cy3/5™ ratios – comparable to data from conventional slides
• Chemically stable reflective coating

Immobilization chemistry

NEXTERION® HiSens Slides are available with most of the NEXTERION® functional coatings.
Suitable probe types
The functional coating on NEXTERION® HiSens Slides is identical to the respective coating on NEXTERION® Slides. Please refer to the table in the section “General information coated slides” in order to find the appropriate coating chemistry for your specific application.
 
                                                                                                                                                                                       Top

Product details

The NEXTERION® HiSens product is an innovative microarray slide based on an ultraflat, high quality borosilicate glass slide coated with reflective dielectric layers (US patent No. 7939339 and European patent No. EP1591773). The reflective layers on NEXTERION®HiSens significantly enhance sensitivity and signal response. The characteristics of the reflective layers have been optimized for the fluorescent wavelengths most commonly used in microarray experiments, and will simultaneously improve the performance in both the Cy3™ and Cy5™ channels. The slide is produced according to industry standard slide dimensions and is available with SCHOTT’s standard high quality functional coatings for DNA and protein microarraying. This means that the NEXTERION® HiSens Slide is fully compatible with all microarray printing technologies and most slide processing protocols, allowing customers a smooth transition from industry-standard transparent microarray slides.

The NEXTERION® HiSens coating is able to enhance signal amplification by exploiting several optical effects:
  • Fluorescence enhancement and reflection of excitation light
    On a standard glass microarray slide, the fluorescently labelled spots absorb only some of the excitation light. By placing a dielectric coating beneath the spots, this “lost” light is reflected back onto the spots. In addition, the multiple layers of the HiSens coating have been specifically designed so that the incoming and reflected excitation light waves overlap and interfere with each other. The interference is constructive at the slide surface, enhancing the excitation by a theoretical factor of up to 6.3 times.

QQ截图20160725154240

  • Reflection of the emission light.
  • The fluorescence emission in the Cy3™ and Cy5™ channels from the labelled spots is redirected towards the detector rather than being lost by passing through the glass or by scattering. This effectively doubles the detected fluorescence signal.

 

undefined

Taken together, these effects can theoretically enhance the fluorescence signal by up to 12.6 times when compared to standard transparent microarray slides.

Increased sensitivity


Significant increases in fluorescent signal intensities and signal-to-background ratios have been demonstrated with the NEXTERION® HiSens E and A+ products, the first two slide surfaces launched by SCHOTT in the HiSens range in 2006 (all slide surfaces are now available). The functional coatings are identical to the standard NEXTERION® slides and were processed with standard slide processing protocols. The results clearly exhibit the same impressive spot size and morphology that users typically associate with NEXTERION® Slide E and Slide A+, but the signal intensity is significantly enhanced thanks to the HiSens coating.

 

undefined

 

Identical oligonucleotide probes were printed on NEXTERION® HiSens A+ and the standard NEXTERION® Slide A+. The slides were hybridized and scanned on an Axon 4000B scanner with identical settings. Images of the NEXTERION® HiSens reflective coating are compared to standard Slide A+. The NEXTERION® HiSens A+ data was normalized against the standard NEXTERION® Slide A+. An 8 to 10 fold increase in signal-to-background ratios was obtained with the NEXTERION®HiSens reflective coating compared to the standard NEXTERION® Slide A+.

 

 

Improved signal response

NEXTERION® HiSens is the ultimate microarray slide for microarray applications where the target material is at a low concentration or cannot be reliably amplified, for example with mRNAs or low abundant proteins. The NEXTERION® HiSens coating may be used to produce reproducible signals at a much lower target concentration than with conventional slides.
The graph shows that for a DNA microarray application, between two and ten fold less target was required to produce the same signal intensity with NEXTERION® HiSens as with a conventional aminosilane microarray slide, resulting in potentially significant cost savings for users.

Preservation of dye ratios

The reflective layers in the NEXTERION® HiSens coating have been designed to enhance the performance of both the Cy3™ and Cy5™ channels equally. The Cy3™ to Cy5™ ratios are preserved, allowing use of standard data normalization methods and direct comparison with data previously produced on conventional slides.

规格参数
品牌 德国肖特(SCHOTT)NEXTERION?   产地 德国  
关键词 生物芯片 蛋白质芯片 反射式光学镀膜 微阵列芯片扫描仪   颜色 白玻  
原片类型 浮法玻璃      
包装参数
体积(m²)
产品重量(kg)
代理商供货
退换货规则说明
申请方式

1,在线申请:您可以在"我的订单"中找到您需要退换修的订单,点击”申请退款/退货”即可。我们的工作人员会在2个工作日 内和您取得联系,你可以随时在线查看你的退换修状态。

注意事项

1,“7天无理由退换货”适用于买家在收到货品后因不满意货品希望退换货的情形。

2,因质量问题产生的退换货,邮费由平台供应商承担(此质量问题为货品破损或残缺)。非商品质量问题的退换货,应由买家承担往返运费。

3,退换货要求退换的商品在平台供应商收到时有完整的外包装、配件、标牌等;待退换的物品被用过、人为破坏或标牌拆卸的不予退换。

(1)符合退货政策的商品必须包装完整、数量准确且不影响再次销售,退货的同时必须退回相应的发票和相关文件。

(2)请对寄回的商品妥善包装,若是退换货过程中由于包装过于简单造成的物流损坏,平台供应商不承担商品完整责任。

(3)发票需单独寄送。退换货时,如涉及发票退回,请您不要将发票放在货物中一起寄送,平台供应商客服人员将和您确认发票寄送地址,避免丢失。

4,退货商品的价款到账时间因支付方式的不同而有所差异,具体应参照相关银行或支付工具的说明提示,平台供应商不对退换货费用的到账时间做任何形式的保证。

特别提醒:为避免由于商品滞留造成的经济损失,所有退换货商品,买家应在所规定之时间内发回(以物流签收时间次日起7天内为准),超过规定时间仍不能将退换商品发出的,平台供应商将不予接受该退换货商品。

联系方式
注意:1 . 使用电话联系可有效保证您的号码隐私不被泄露
          2 . 拨打后可在后台进行拨打记录查询
          3 . 成交后在会员中心确认可获得积分
联系人:陈思 (市场部/市场经理)
电话:15989190183
给我留言
注意:1. 供应商将在24小时内给您回复,回复内容将以短信形式发送至您手机。
2. 对产品的尺寸,质量,规格,库存等方面技术问题进行咨询,我们有专人进行回复,因厂家随时会更改产品的相关信息,请以厂家实际产品为准。
咨询产品:
蛋白质芯片Reflective optical coating应用在微阵列芯片扫描仪
联系电话:
联系人:
留言详情: